Portable MAP Analyser

Modified Atmosphere Packaging / MAP Analysers

AGC Instruments offers a range of handheld Headspace Analysers for use in the Modified Atmosphere Packaging (MAP) or Controlled Atmosphere Packaging Industry to suit the various requirements of gas flushed products within the food packaging and food processing industry. Whether required to measure Oxygen (O2), Carbon Dioxide (CO2) or a mixture of both, AGC Instruments offers a high quality headspace analyser that can be depended on to provide hassle free, accurate and consistent measurements.The range includes the Map-Pak O2 and the Map-Pak Combi which measures both CO2, O2 and N2 levels (the latter being as a balance gas reading). The MAP quality control offerings from AGC Instruments are perfectly suited to a wide variety of foods such as – meat, poultry, seafood, cheese, fruit, vegetables, snacks, convenience foods and many more.

Features and benefits of the Map-Pak include:
  • Portable and lightweight
  • Easy to use operator interface
  • Bright and sharp display with backlight
  • 7-8 hours operation time
  • Power saver feature for even longer operation time
  • Alarm feature with pass/fail indicator
  • Built in database for storing measurements
  • High quality analyser at a cost effective price
  • MP Downloader Software for the Map-Pak range is included
  • An optional Thermal Printer is available for printing results on the go

The Map-Pak range is the 4th generation of MAP analysers and AGC Instruments has over 50 years experience in Total Gas Analysis Solutions hence quality and reliability is assured.




http://www.agc-instruments.com/modified-atmosphere-packaging-map-analysers-0

Thermal Conductivity Detectors (TCD)

Thermal Conductivity Detectors (TCD)
As a leading manufacturer and supplier of Thermal Conductivity Detectors (TCDs) worldwide, AGC Instruments is able to advise and design a suitable configuration should it not be standard.
The Thermal Conductivity Detector (TCD) is simple in construction, inexpensive yet rugged, universal, has excellent sensitivity and is relatively linear through a wide range. In its use, the sample is not destructed. It is one of the most widely used detectors in the world today.

The Thermal Conductivity Detector (TCD) comprises of a metallic block which contains a cavity through which gas flows. Positioned in this gas flow are heated elements (Hot Wire Filaments or Thermistors). As each gas has a known thermal conductivity, the method of difference in these thermal conductivities is the principal upon which it is based. For this method, two heated elements in two cavities are required. In Chromatography applications, the carrier gas passes through one cavity and the sample after being passed through the column flows through the second cavity. For Process applications a Reference (or Span) Gas and Sample Gas are used.


http://www.agc-instruments.com/thermal-conductivity-detectors-tcd

Gas Chromatographs

Gas Chromatographs

AGC Instruments introduces the new NovaCHROM range of Gas Chromatographs. The NovaCHROM GC is a culmination of years of experience in high sensitivity Gas Chromatography specific for the Analysis of impurities in a wide range of gas applications. This GC uses industry driven and proven methods of analysis for the quality control of gases using different detector technologies adapted to the required applications. The large colour interactive touch screen provides an easy-to-use user interface for guided functionality of the many features which enable the precise monitoring of applications. This ensures that the NovaCHROM GC provides a top class service to you at all times.
Each NovaCHROM GC is equipped with specific chromatography components depending on the application. Moreover, the packed columns with their multiple column ovens and individual temperature controllers also maintain exceptional stability, sensitivity, accuracy and repeatability.
With an optimised consumption of carrier and supply gases, the NovaCHROM also provides an economical platform with a low cost of ownership and long life span.
The Integrated Diagnostics and Configurable Alarms Systems pinpoint any areas which require attention to allow swift identification and resolution of any process issues. With these features, the NovaCHROM can operate unattended for long periods of time. This makes this GC Platform very versatile and robust to meet the exacting needs of the operation.
AGC NovaCHROM Gas Chromatograph range:
NovaCHROM 1000 with Discharge Ionisation Detector (DID)
NovaCHROM 2000 with Argon Discharge Detector (ADD)
NovaCHROM 3000 with Flame Ionisation Detector (FID)
NovaCHROM 4000 with Thermal Conductivity Detector (TCD)
NovaCHROM 5000 with Flame Photometric Detector (FPD)
For further information please visit: http://www.agc-instruments.com/novachrom-gc-range   

Wednesday, 30 March 2011

Gas Leak Detectors

Gas Leak Detectors
About the Mini Gas Leak Detector
AGC Instruments offers the Mini Gas Leak Detector (Model 21-072) which will easily find any gas that is leaking from a pressurised system. By using a thermal conductivity detector, this instrument will respond with speed to any gas mixture that has a thermal conductivity different to air.

With a high signal to noise ratio, via amplification we are able to deliver a maximum usable sensitivity. Helium leaks of 1 x 10-5 cc/sec are easily detected. Other gases include Refrigerant leaks of 1.1 x 10-4 cc/sec and Argon leaks of 1.0 x 10-4 cc/sec.

Principle of Operation
The probe is passed over the area to be checked, a sample is drawn in automatically into the thermal conductivity detector. A signal is registered on the meter when a leak is detected.

This clean and easy to use system ensures that no contamination is left that traditionally is caused when using a soap solution. By using the probe, it is easy to reach difficult locations within a system. The probe is small enough to find the exact location of a leak.


 http://www.agc-instruments.com/gas-leak-detectors

Hot Wire Filaments & Thermistors

Hot Wire Filaments & Thermistors

About Hot Wire Filaments & Thermistors
AGC Instruments is a leading supplier of Hot Wire Filaments, Thermistors and Thermal Conductivity Detectors (TCD) to leading Instrument manufacturers of Gas Chromatographs and Gas Analysers Worldwide.

Hot Wire Filaments
A choice of materials is available depending on the application in question. The choice includes: Gold-Sheathed Tungsten (AuW), Tungsten (W), Rhenium-Tungsten (WX), Nickel (Ni) and Nickel Alloy.
Each type has specific characteristics such as corrosion resistance, oxidation resistance, catalytic reactions and sensitivity for use which are dependent on the application required.

Hot Wire Filaments required for corrosive applications are best suited to be manufactured in Gold-sheathed tungsten, with special resistance to Oxygen. The Filaments are sold as matched pairs with standard 50mm (2”) leads or at lengths more suited to the customer’s requirement.

Thermistors
The Thermistor is a thermally sensitive resistor that has a high negative coefficient of resistance. They are manufactured from a mixture of the oxides of Manganese, Nickel and Cobalt. They are sintered in an oxidising atmosphere in the form of small beads (0.012” dia.). A covering of glass is then placed over the bead to protect it from further oxidation and reduction.

The characteristic of thermistors is such that they can be operated at relatively low operating temperatures, they have high sensitivity and are suitable for sub-ambient temperatures.

Customised Hot Wire Filaments
AGC Instruments can customise to a customer specific requirement. We can manufacture Hot Wire Filaments to meet your exact requirement or to best suit your needs.

For more information on our customised solutions please contact us directly.



http://www.agc-instruments.com/hot-wire-filaments

Chromatography Software

TrendVision Chromatography Software

TrendVision Chromatography Software is a complete Chromatography Integration package that provides the Gas Chromatograph Operator with all the tools needed to interpret the Data and Results from the Chromatograph. It integrates all the instrument control, data handling, display, reporting and export functions needed in the usual industrial and laboratory environment into one package. The extended capabilities enable all Methods to be stored with valve timings to so that the GC can operate in an automatic mode. Up to four GC channels are available and allow data from up to eight continuous Gas Analysers to be displayed within the Software. This means that third party equipment such as Moisture, O2 and CO2 analyser results can be displayed beside the data from the GC. This, in turn, provides the Operator with meaningful information that can be transmitted back to the Control Room or DCS if needed.
TrendVision provides a unified chromatography method whereby all settings are contained in a single method, including event tables, calibration tables and integration settings. In addition, this software enables our GC systems to run in a fully unattended mode. It can also take control of the AGC Instruments GC systems and automatically perform the required analysis using the pre-programmed methods. This is coupled with the ability to send results back to a DCS or control room using fieldbus protocols or traditional 4-20 mA signalling. If On-Line operation is not required then the software runs equally well in its Stand-Alone mode with the same functionality and ease of use.
TrendVision PLUS is the most recent release of the well recognised Chromatography Data Capture Software from AGC Instruments. Rugged industrial level modular and scalable hardware is used with an Embedded Windows Operating System which is easy to use and set up. Once your system is installed, usage in the daily environment is very easy with minimal training required. It encompasses all the important functions required in this demanding gas analysis environment, enabling many standard features to be easily applied with the end products of excellent chromatography results and straightforward reporting.

For more information on our TrendVision Chromatography Software please visit:

http://www.agc-instruments.com/trendvision-chromatography-software

Trace N2 Gas Analyser

Trace Nitrogen Gas Analysers

About:
The AGC Series 100 SED is engineered for the continuous monitoring of N2 in Ar or N2 in He.
Its N2 specific detector has been derived from our extremely successful High Frequency Argon Discharge Detector (ADD) system, the Series 100 HF-ADD Gas Analyser.

AGC Instruments has been providing this system configuration for several years to the gas manufacturing companies and especially to argon and helium specific plants throughout the world.

Principal:
The emission wavelength intensity of the Nitrogen molecule is selected to determine the trace amount of Nitrogen in Argon or Helium Matrix Gas. The response is proportional to the nitrogen concentration in low ppb to high ppm range.

Technique:
Using a spectral emission technique, a unique quartz ionisation chamber is utilised in which the sample gas is ionised by a high frequency tuned oscillator with the resultant emission wavelength intensity of the nitrogen
component is directed through a narrow band pass filter and is detected via a photomultiplier tube.


http://www.agc-instruments.com/trace-nsub2sub-gas-analysers

Binary Stream Gas Analysers

Binary Stream Gas Analysers

About the 20 Series

The 20 Series Thermal Conductivity gas analyser was developed for the determination of binary gas mixtures and gas purity measurements. This analyser compares the difference in the thermal conductivity between the sample and reference gases, which are exposed to the detector elements.

Principle of Operation
Using Hotwire or thermistor elements, an analyser which has accuracy and sensitivity, coupled with a robust platform is achieved with a response time of < 30 second (T90).

Produced as bench top Gas Analyser (option for 19” rack platform), with all stainless steel tubing with Swagelok fittings allows this analyser to be used in many environments. We customise each analyser to meet the specific requirements of our customer. Utilising the option of a pump, the analysis of samples where the gas pressure is very low is possible.

What does the 20 Series offer
The Binary Stream Gas Analyser from AGC Instruments is used for the analysis of binary streams of industrial gases, cylinder identification & atmosphere control applications on a non continuous basis.

Models Available
Two types are available (1) single pass (sealed reference/gas economical) analyser or a (2) dual pass (flowing reference/more thermally stable) analyser. Both with a flowmeter & needle valve, a pump (optional), and a 5 way valve for zero, span/calibration & sample gases, the units are built for rugged use and simple to use.


http://www.agc-instruments.com/20-series-binary-stream-gas-analyser



About the 50 Series
The newest model of the legendary Binary Stream Gas Analyser from AGC Instruments is used to measure N2, H2, He, CO2, Ar or other gases in Binary gas mixtures or pure gases. We monitor impurities in a major gas based on the difference of thermal conductivities.

Using hotwire or thermistor elements, an analyser which has accuracy and sensitivity, coupled with a robust platform is achieved with a response time of < 30 second (T90). To interface with the analyser is via the new 5.7” QVGA LCD touch screen display, where all status, alarm conditions, diagnostics and direct reading of results are available with ease.

Using a high quality flow detection devices with Alarms, the gas flows are measured & displayed to the LCD display ensuring accuracy and stability to allow great confidence in all results.

The 50 Series model contains a temperature regulated TCD which allows continuous monitoring of the gas stream. Through the use of solenoid valves, drift has been eliminated as a constant reference to Zero Gas is utilised for greater accuracy. Using temperature control of the measuring sensor, excellent stability is guaranteed with <1% drift over a 24 hour period.

Principle of Operation
The Detector consists of an electrically heated hotwire (or thermistor) element in a temperature regulated metal housing. The detection principle is based on any change in the thermal conductivity of a gas flowing through the detector will change the rate of heat loss from the element to the metal housing. The signal resulting from the temperature change is proportional to the change in sample gas conductivity.

Features:
• 5.7” QVGA LCD Display
• Alarm/Fault Status LED
• Direct value reading - % or ppm
• Debug Diagnostic function
• Autovalidation/Autocheck
• Choice of TC Detectors
• Low Sensitivity
• Temperature Controllers option
• Solenoids for Switching of Auto Zero/Span Gas
• 2 off 4-20 mA outputs
• Alarm Status



 http://www.agc-instruments.com/50-series-binary-stream-gas-analyser-supnewsup

Total Hydrocarbon Gas Analysers

THC Gas Analysers

About the 23 Series
The new Total Hydrocarbon Gas Analyser from AGC Instruments is the latest in digital and modern technology but based on the well-known and approved analytical performance of its previous generation.
Utilising the finest tools available, the ease with which customers are able to achieve the best results has been made easier. This new and easy to use THC Analyser has an interactive touch screen display where all controls and results easily brought to the customers. Literally at the touch of a finger!!!!

Designed to continuously measure and monitor concentrations of Hydrocarbons in a gas stream. It is also available to measure CO & CO2. Our Instrument will provide accuracy with long term performance for applications ranging from gas producers to laboratory uses. For ppb applications, the internal cabinet is heated to provide a stable ambient temperature to offset any working temperatures.

Principle of Operation
Based on the principle of the Flame Ionisation Detector (FID) where ionised carbon atoms are produced when burned in a Hydrogen flame. Following calibration, the results are displayed as %, ppm or ppb.

What does the 23 Series offer
• Continuous Hydrocarbon Monitoring
• Selective to Hydrocarbons only
• Long Term Reliability and Stability even in low ppm ranges
• Approved low detection limit
• Versatile Fuel MixturesSemiconductor Industry
• Methaniser option to measure CO and CO2
• Heated version available, to analyse Gas Streams where Sample Temperature needs to be maintained at the Operating Temperature

Features:
• 5.7” QVGA Touch Screen Display
• Easy to Use interface provides user access to all features
• Display monitoring flow control on all gas lines
• Visual Alarms & Relay contacts provided
• Internal Zero/Span/Sample solenoids provided
• Autocalibration & Validation check feature
• Live Data Logger via RS232
• Autoranging 0.00 - 20,000 ppm
• 2 off Adjustable 4-20mA output (Isolated - Passive)